Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 72-50-24-200-002-B00 LPT Inner Diffuser Duct Support - Examine, Inspection-002
General
This TASK gives the procedure for the inspection of the inner diffuser support. For the other LP turbine inner static seal parts, refer to TASK 72-50-24-200-000 (INSPECTION-000).
Fig/item numbers in parentheses in the procedure agree with those used in the IPC.
A ** following any repair referenced in this inspection indicates that the repair is not yet published in the current revision of this manual and the part must be rejected. Contact IAE for additional information concerning FAA approved data.
The policy that is necessary for inspection is given in the SPM TASK 70-20-00-200-501.
All the parts must be cleaned before any part is examined. Refer to the TASK 72-50-24-100-000 (CLEANING-000)
All parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.
The procedure for those parts which must have a crack test is given in SUBTASK 72-50-24-230-065. Do not crack test before the part is visually examined.
Do not discard any part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.
Parts which should be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a later date.
All parts must be examined to make sure that all the repairs have been completed satisfactorily.
The practices and processes referred to in the procedure by the TASK numbers are in the SPM.
Reference
Refer to the SPM for data on these items.
Definitions of Damage, SPM TASK 70-02-02-350-501
Record and Control of the Lives of Parts, SPM TASK 70-05-00-220-501
Inspection of Parts, SPM TASK 70-20-00-200-501
Some data on these items is contained in this TASK. For more data on these refer to the SPM.
Method of Testing for Crack Indications
Chemical Processes
Surface Protection
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
| Name | Manufacturer | Part Number / Identification | Quantity | Remark |
|---|---|---|---|---|
| Dial gage | LOCAL | Dial gage | ||
| Dial indicator with needle insert | LOCAL | Dial indicator with needle insert | ||
| Dial caliper | LOCAL | Dial caliper |
Consumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Clean the parts. Refer to TASK 72-50-24-100-000 (CLEANING-000).
SUBTASK 72-50-24-230-065-001 Do a Crack Test on the Inner Diffuser Support (Fluorescent Penetrant)
Clean the parts. Refer to TASK 72-50-24-100-000 (CLEANING-000).
SUBTASK 72-50-24-230-065-002 Do a Crack Test on the Inner Diffuser Support (Fluorescent Penetrant)
Repair, VRS4322 TASK 72-50-24-300-032 (REPAIR-032)
Other than in (1)
Nicked or dented, use dial gage and dial gage indicator with the needle insert.
SUBTASK 72-50-24-220-102 Examine the Inner Diffuser Support for Surface Damage
Refer to Figure.
Refer to TASK 72-50-24-840-002
Less than in (1)
Worn, measure dimension D1. Usedial caliper.
SUBTASK 72-50-24-220-103 Examine the Inner Diffuser Support at Location D1
Repair, VRS4318 TASK 72-50-24-300-037 (REPAIR-037)
More than 0.010 in. (0.25 mm)
Axial movement, use dial gage and dial indicator with needle insert.
Repair, VRS4318 TASK 72-50-24-300-037 (REPAIR-037)
Worn thread
SUBTASK 72-50-24-220-104 Examine the Clinch Nuts of the Inner Diffuser Support for Damage
Repair, VRS4319 TASK 72-50-24-300-036 (REPAIR-036)
Less than in (1)
Worn, use dial caliper.
SUBTASK 72-50-24-220-105 Examine the Headless Shoulder Pin of the Inner Diffuser Support
Refer to: Figure
Repair, VRS4321 TASK 72-50-24-300-035 (REPAIR-035)
More than in (1)
Fretted, use dial gage and dial indicator with needle insert.
SUBTASK 72-50-24-220-106 Examine the Inner Diffuser Support at Location A1
Refer to: Figure
SUBTASK 72-50-24-220-107 Examine the Inner Diffuser Support at Location A2
Refer to: Figure
Repair, VRS4320 TASK 72-50-24-300-034 (REPAIR-034)
Less than in (1)
Worn, measure the dimension D2. Use dial caliper.
SUBTASK 72-50-24-220-108 Examine the Inner Diffuser Support at Location D2
Figure: Examine the inner diffuser support
Examine the inner diffuser support