Export Control
EAR Export Classification: Not subject to the EAR per 15 C.F.R. Chapter 1, Part 734.3(b)(3), except for the following Service Bulletins which are currently published as EAR Export Classification 9E991: SBE70-0992, SBE72-0483, SBE72-0580, SBE72-0588, SBE72-0640, SBE73-0209, SBE80-0024 and SBE80-0025.Copyright
© IAE International Aero Engines AG (2001, 2014 - 2021) The information contained in this document is the property of © IAE International Aero Engines AG and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of © IAE International Aero Engines AG. (This does not preclude use by engine and aircraft operators for normal instructional, maintenance or overhaul purposes.).Applicability
All
Common Information
TASK 73-22-49-200-106 Fuel System Sensing Air Tubes - Examine The EEC P2.5 And P12.5 Pressure Air Tube, Inspection-006
Effectivity
FIG./ITEM | PART NO. |
09-100 | 6A2133 |
09-500 | 6A2122 |
09-500 | 6A6007 |
10-100 | 6A2126 |
10-100 | 6A6213 |
10-500 | 6A1692 |
10-500 | 6A6214 |
11-100 | 6A1693 |
12-100 | 6A2135 |
General
This TASK gives the procedure for the inspection of the P2.5 and P12.5 pressure air tube assembly. For the other fuel system air tubes and parts, refer to Inspection-000 TASK 73-22-49-200-100 and in the Component Maintenance Manual Inspection-000 TASK 73-22-49-200-400.
Fig./item numbers in parentheses in the procedure agree with those used in the IPC. Only the primary Fig./item numbers are used. For the service bulletin alpha variants refer to the IPC.
The policy that is necessary for Inspection is given in the SPM TASK 70-20-01-200-501.
All the parts must be cleaned before they are examined. Refer to Cleaning-000 TASK 73-22-49-100-100.
All the parts must be visually examined for damage, corrosion and wear. Any defects that are not identified in the procedure must be referred to IAE.
The procedure for those parts which must have a crack test is given in the relevant SUBTASK. Do the crack test before the part is visually examined.
Do not discard a part until you are sure there are no repairs available. Refer to the instructions in Repair before a discarded part is used again or oversize parts are installed.
Parts which must be discarded can be held although no repair is available. The repair of a discarded part could be shown to be necessary at a subsequent date.
All parts must be examined to make sure that all the repairs are completed satisfactorily.
Practices and processes referred to in the procedure by the TASK/SUBTASK number are in the SPM.
NOTE
References
Refer to the SPM for data on these items:
Definitions of Damage - Specified Types of Damage, SPM TASK 70-02-02-350-501.
Inspection Policy and Inspection of Parts, SPM TASK 70-20-01-200-501.
Some data on these items is contained in this TASK. For more data on these items refer to the SPM:
Methods of Testing for Crack Indications
Chemical Processes
Surface Protection
Preliminary Requirements
Pre-Conditions
NONESupport Equipment
NONEConsumables, Materials and Expendables
NONESpares
NONESafety Requirements
NONEProcedure
Clean the part. Refer to Cleaning-000 TASK 73-22-49-100-100.
P2.5 and P12.5 pressure air tube assembly (09-100), (09-500), (10-100), (10-500) (11-100) and (12-100).
Do the crack test on the parts that are given below. Use the applicable penetrant inspection procedure.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Cracked
SUBTASK 73-22-49-230-053-001 Examine the P2.5 and P12.5 Pressure Air Tube Assembly for Cracks
Clean the part. Refer to Cleaning-000 TASK 73-22-49-100-100.
P2.5 and P12.5 pressure air tube assembly (09-100), (09-500), (10-100), (10-500) (11-100) and (12-100).
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Cracked
Do the crack test on the parts that are given below. Use the applicable penetrant inspection procedure.
SUBTASK 73-22-49-230-053-002 Examine the P2.5 and P12.5 Pressure Air Tube Assembly for Cracks
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Pitted
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Not more than 0.500 in. (12.70 mm) from fittings or bends.
Accept
In areas other than in Step: Of large smooth area if the maximum diameter is 10 times the depth and bore is not decreased by more than 10 percent at any one point.
Accept
In areas other than in Step: Of small smooth area not more than 0.125 sq in. (80.0 sq mm) if depth is not more than 0.025 in. (0.64 mm).
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Dented
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
On the outer surface of a bend with rounded bottom and not more than 0.003 in. (0.076 mm) in depth.
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
In areas other than in Step with rounded bottom and not more than 0.003 in. (0.076 mm) in depth.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Nicked
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
On the outer surface of a bend not more than 0.003 in. (0.076 mm) in depth.
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
In areas other than in Step not more than 0.003 in. (0.076 mm) in depth.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Limits more than Step.
Galled
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
On the outer surface of a bend not more than 0.002 in. (0.051 mm) in depth.
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
In areas other than Step Not more than 0.002 in. (0.051 mm) in depth.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Scratched or scored.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
More than in Step.
Wrinkled
Examine the tube surface.
SUBTASK 73-22-49-220-056 Examine the P2.5 and P12.5 Pressure Air Tube Assembly Tube Surface
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Pick-up
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Crossed or stripped
Threads
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Damaged
Lockwire holes
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Burred
Flange bolt holes
Union adapters
Repair, VRS6226 (Repair-004) TASK 73-22-49-300-004.
Pick-up
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Crossed or stripped
Threads
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Damaged
Lockwire holes
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Galled
Faces that seal.
Union nuts.
SUBTASK 73-22-49-220-057 Examine the P2.5 and P12.5 Pressure Air Tube Assembly Tube End Connectors
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Distorted, small distortion can be removed if cracks are not caused.
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
Cracked
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Bolt holes burred.
SUBTASK 73-22-49-220-058 Examine the P2.5 Pressure Air Tube Assembly (09-100) Tube Lug
Clear with dry compressed air.
Plugged
SUBTASK 73-22-49-220-059 Examine the P2.5 and P12.5 Pressure Air Tube Assembly Tube Bore
SUBTASK 73-22-49-220-092 Examine the P2.5 and P12.5 Pressure Air Hose Assembly (11-500) and (12- 500)
NOTE
Procedure for flexible hoses transferred to Inspection-008 TASK 73-22-49-200-108.Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Not more than 0.002 in. (0.051 mm).
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
More than in Step.
Galled
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Not more than 0.002 in. (0.051 mm).
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
More than in Step.
Scored
Repair, VRS6225 (Repair-001) TASK 73-22-49-300-003.
Not more than 0.002 in. (0.051 mm).
SPM, VRS7001 (Repair-001) TASK 70-35-24-300-501.
More than in Step.
Nicked
SUBTASK 73-22-49-220-093 Examine the P2.5 and P12.5 Pressure Air Tube Assembly (10-100) and (12- 100) Moisture Trap